dc.contributor.authorFernández-Berni, J.
dc.contributor.authorCarmona-Galán, R.
dc.contributor.authorLeñero-Bardallo, Juan A.
dc.contributor.authorKleihorst, R.
dc.contributor.authorRodríguez-Vázquez, Á.
dc.date.accessioned2014-10-22T12:00:27Z
dc.date.accessioned2020-09-09T21:30:53Z-
dc.date.available2014-10-22T12:00:27Z
dc.date.available2020-09-09T21:30:53Z-
dc.date.issued2014-
dc.identifier.isbn978-989-26-0884-6 (PDF)
dc.identifier.urihttps://hdl.handle.net/10316.2/34180-
dc.description.abstractAdvances in electronics, sensor technologies, embedded hardware and software are boosting the application scenarios of wireless sensor networks. Specifically, the incorporation of visual capabilities into the nodes means a milestone, and a challenge, in terms of the amount of information sensed and processed by these networks. The scarcity of resources – power, processing and memory – imposes strong restrictions on the vision hardware and algorithms suitable for implementation at the nodes. Both, hardware and algorithms must be adapted to the particular characteristics of the targeted application. This permits to achieve the required performance at lower energy and computational cost. We have followed this approach when addressing the detection of forest fires by means of wireless visual sensor networks. From the development of a smoke detection algorithm down to the design of a low-power smart imager, every step along the way has been influenced by the objective of reducing power consumption and computational resources as much as possible. Of course, reliability and robustness against false alarms have also been crucial requirements demanded by this specific application. All in all, we summarize in this paper our experience in this topic. In addition to a prototype vision system based on a full-custom smart imager, we also report results from a vision system based on ultra-low-power low-cost commercial imagers with a resolution of 30×30 pixels. Even for this small number of pixels, we have been able to detect smoke at around 100 meters away without false alarms. For such tiny images, smoke is simply a moving grey stain within a blurry scene, but it features a particular spatio-temporal dynamics. As described in the manuscript, the key point to succeed with so low resolution thus falls on the adequate encoding of that dynamics at algorithm level.eng
dc.language.isoeng-
dc.publisherImprensa da Universidade de Coimbrapor
dc.relation.ispartofhttp://hdl.handle.net/10316.2/34013por
dc.rightsopen access-
dc.subjectForest fireseng
dc.subjectSurveillance systemseng
dc.subjectWireless sensor networkseng
dc.subjectAutomatic early detectioneng
dc.subjectArtificial visioneng
dc.subjectLow-power sensorseng
dc.subjectVision algorithmseng
dc.titleTowards an ultra-low-power low-cost wireless visual sensor node for fine-grain detection of forest firespor
dc.typebookPartpor
uc.publication.firstPage1571-
uc.publication.lastPage1581-
uc.publication.locationCoimbrapor
dc.identifier.doi10.14195/978-989-26-0884-6_173-
uc.publication.sectionChapter 5 - Fire Suppression and Safetypor
uc.publication.digCollectionPBpor
uc.publication.orderno173-
uc.publication.areaCiências da Engenharia e Tecnologiaspor
uc.publication.bookTitleAdvances in forest fire research-
uc.publication.parentItemId53868-
uc.itemId70219-
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:Advances in forest fire research
Files in This Item:
File SizeFormat 
978-989-26-0884-6_173.pdf2.49 MBAdobe PDFView/Open
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.