Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316.2/44451
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Veneziani, G. R. | |
dc.contributor.author | Rodrigues Jr., O. | |
dc.contributor.author | Sakuraba, R. K. | |
dc.contributor.author | Campos, L. L. | |
dc.date.accessioned | 2018-11-05T16:34:53Z | |
dc.date.accessioned | 2020-09-05T07:52:11Z | - |
dc.date.available | 2018-11-05T16:34:53Z | |
dc.date.available | 2020-09-05T07:52:11Z | - |
dc.date.issued | 2018 | - |
dc.identifier.isbn | 978-989-26-1602-5 (PDF) | |
dc.identifier.isbn | 978-989-26-1601-8 | |
dc.identifier.uri | https://hdl.handle.net/10316.2/44451 | - |
dc.description.abstract | In this study we evaluated the feasibility of using 3D printer (FDM) and tissue equivalent material to the development phantoms to be used in radiation therapy or diagnosis. Results evaluated by CT were quite promising and open the way for the development of custom phantoms and low cost. | eng |
dc.description.abstract | Nesse trabalho foi avaliada a viabilidade do uso de impressora 3D (FDM) e materiais tecido equivalentes para o desenvolvimento de simuladores para serem aplicados em radioterapia e/ou diagnóstico. Os resultados avaliados por CT foram bastante promissores e abrem caminho para o desenvolvimento de simuladores personalizados e de baixo custo. | por |
dc.language.iso | por | - |
dc.publisher | Imprensa da Universidade de Coimbra | por |
dc.relation.ispartof | http://hdl.handle.net/10316.2/44443 | por |
dc.rights | open access | - |
dc.subject | 3D printer | eng |
dc.subject | Phantom | eng |
dc.subject | Equivalent Tissues | eng |
dc.subject | Impressora 3D | por |
dc.subject | Simuladores | por |
dc.subject | Material tecido equivalente | por |
dc.title | Desenvolvimento de simulador aplicados a radiodiagnostico e radioterapia utilizando impressora 3D | por |
dc.title.alternative | Development of phantom applied to radiodiagnostics and radiotherapy using 3Dprinter | eng |
dc.type | bookPart | por |
uc.publication.firstPage | 77 | - |
uc.publication.lastPage | 83 | - |
uc.publication.location | Coimbra | por |
dc.identifier.doi | 10.14195/978-989-26-1602-5_8 | - |
uc.publication.section | Capítulo 2 - Dosimetria e instrumentação | por |
uc.publication.digCollection | PB | por |
uc.publication.orderno | 8 | - |
uc.publication.area | Ciências Naturais | por |
uc.publication.bookTitle | Proteção contra radiações na comunidade dos países de língua portuguesa | - |
uc.publication.manifest | https://dl.uc.pt/json/iiif/10316.2/44451/201178/manifest?manifest=/json/iiif/10316.2/44451/201178/manifest | - |
uc.publication.thumbnail | https://dl.uc.pt/retrieve/11018455 | - |
uc.publication.parentItemId | 55071 | - |
uc.itemId | 68244 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
Appears in Collections: | Proteção contra radiações na comunidade dos países de língua portuguesa |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
desenvolvimento_de_simulador_aplicados.pdf | 415.42 kB | Adobe PDF |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.